Vanguard TTRA-S2 (ATRT-03 S2, ATRT-03A S2, ATRT-03B S2, Tri User Manual

Browse online or download User Manual for Software Vanguard TTRA-S2 (ATRT-03 S2, ATRT-03A S2, ATRT-03B S2, Tri. Vanguard TTRA-S2 (ATRT-03 S2, ATRT-03A S2, ATRT-03B S2, Tri-Phase) User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Transformer Turns Ratio Analyzer Series 2
(TTRA-S2)
VERSION 1.x SOFTWARE MANUAL
For Use with Vanguard’s
ATRT-03 S2, ATRT-03A S2, ATRT-03B S2, and Tri-Phase
Transformer Turns-Ratio Meters
Vanguard Instruments Company, Inc.
1520 S. Hellman Ave.
Ontario, California 91761, USA
TEL: (909) 923-9390
FAX: (909) 923-9391
June 2009
Revision 2
Page view 0
1 2 3 4 5 6 ... 48 49

Summary of Contents

Page 1

Transformer Turns Ratio Analyzer Series 2 (TTRA-S2) VERSION 1.x SOFTWARE MANUAL For Use with Vanguard’s ATRT-03 S2, ATRT-03A S2, ATRT-03B S2, and

Page 2 - TABLE OF CONTENTS

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 7

Page 3 - LIST OF FIGURES

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 8 3.2 System Configuration Before using the program, the system configuration parameters should be rev

Page 4 - WARNING

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 9 d. Test Record Path The default location where test records are stored on the PC hard drive is listed in

Page 5 - 1.0 INTRODUCTION

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 10 4.0 WORKING WITH TEST RECORDS The TTRA-S2 software can be used to retrieve test records from the A

Page 6 - SOFTWARE INSTALLATION

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 11 So if you would like the filename to be “sample_test001.tst”, enter the word sample_test in the “Filenam

Page 7

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 12 4.2 Recalling a Test Record From the PC Hard Drive Test records stored on the PC hard drive can be

Page 8

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 13 4.3 Saving a Test Record 4.3.1. Saving a Test Record With Its Original Filename 1. If changes have be

Page 9

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 14 4.4 Copying Test Records To copy a test record from one location on the PC hard drive to another l

Page 10

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 15 4.5 Deleting Test Records To delete a test record stored on the PC hard drive: 1. From the File-Util me

Page 11

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 16 4.6 Exporting a Test Record in Microsoft® Excel® Format You can export a test record in Microsoft®

Page 12

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 i TABLE OF CONTENTS CONVENTIONS USED IN THIS DOCUMENT ...

Page 13

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 17 Figure 1. Test Record in TTRA-S2 Software and Microsoft Excel

Page 14

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 18 4.7 Exporting a Test Record to a Text File You can also export a test record to a text file. To ex

Page 15

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 19 Figure 2. Test Record in TTRA-S2 Software and in Text Format

Page 16

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 20 4.8 Working with Tabulated Test Results Once a test record has been retrieved (see sections 4.1 an

Page 17

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 21 Figure 3. A Typical Test Record Printout

Page 18

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 22 4.8.2. Displaying the Deviation Graph The deviation graph is a useful tool for analyzing the trans

Page 19

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 23 5.0 WORKING WITH TEST PLANS The TTRA-S2 software can be used to create transformer, load tap changer, an

Page 20

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 24 So if you would like the filename to be “sample_plan001.pln”, enter the word sample_plan in the “F

Page 21

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 25 5.2 Recalling a Test Plan From the PC Hard Drive Test plans stored on the PC hard drive can be recalled

Page 22

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 26 5.3 Transferring Test Plans to an ATRT To transfer a test plan from the PC hard drive to an ATRT:

Page 23

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL ii LIST OF FIGURES Figure 1. Test Record in TTRA-S2 Software and Microsoft Excel ...

Page 24

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 27 3. Click on the memory location where you would like the test plan to be transferred to and click on th

Page 25

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 28 5.4 Saving a Test Plan 5.4.1. Saving a Test Plan With Its Original Filename 1. If changes have

Page 26 - 5.0 WORKING WITH TEST PLANS

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 29 5.5 Copying Test Plans To copy a test plan from one location on the PC hard drive to another location: 1

Page 27

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 30 5.6 Exporting Test Plans to a USB Thumb (Flash) Drive You can export test plans to a USB thumb (Fl

Page 28

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 31 3. Select your thumb drive and then click on the “OK” button. Do NOT select a folder in your thumb driv

Page 29

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 32 5.7 Deleting Test Plans To delete a test plan stored on the PC hard drive: 1. From the File-Util

Page 30

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 33 5.8 Exporting a Test Plan to a Text File You can export a test plan to a text file by using the steps be

Page 31

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 34 5.9 Creating Test Plans The TTRA-S2 software can be used to create test plans for transformers, lo

Page 32

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 35 5. To set the test voltage, click on the “Voltage:” drop-down list and select the desired test voltage (

Page 33

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 36 5.9.2. Creating a Test Plan for a Load Tap Changer To create a test plan for a load tap changer (L

Page 34

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 1 CONVENTIONS USED IN THIS DOCUMENT This document uses the following conventions: • Microsoft® Windows XP a

Page 35

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 37 8. Click on the “OK” button. An untitled test plan with the selected parameters will be created and disp

Page 36

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 38 5.9.3. Creating a Test Plan for a Voltage Regulator To create a test plan for a voltage regulator:

Page 37

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 39 6. Click on the “OK” button. An untitled test plan with the selected parameters will be created and disp

Page 38

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 40 6.0 RUNNING TESTS The TTRA-S2 software can be used to run transformer, load tap changer, and voltag

Page 39

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 41 4. If the test plan you would like to use is not in the current directory, click on the “Path” button at

Page 40

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 42 9. A notepad is also available for entering any relevant information about the test. To access the

Page 41

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 43 6.2 Running a Transformer Test Using the Create Test Option The Create Test option from the Test-Xfmr me

Page 42

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 44 8. Once all tests have been performed, click on the File menu and select either Save or Save As...

Page 43 - 6.0 RUNNING TESTS

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 45 7.0 USING THE TRANSFORMER TURNS RATIO CALCULATOR The TTRA-S2 software features a turns ratio calculator

Page 44

1520 S. Hellman Ave • Ontario, CA 91761 • USA Phone: 909-923-9390 • Fax: 909-923-9391 www.vanguard-instruments.com

Page 45

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 2 1.0 INTRODUCTION The Transformer Turns Ratio Analyzer Series 2 (TTRA-S2) software is a Windows-based

Page 46

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 3 2.0 SOFTWARE INSTALLATION Follow the steps below to install the TTRA-S2 software on your PC. 1. Insert t

Page 47

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 4 6. Click on the “Next” button to continue. The following screen will be displayed showing the locat

Page 48

TTRA-S2 VERSION 1.x SOFTWARE MANUAL REV 2 5 8. Click on the “Install” button. The InstallShield Wizard will copy files to your hard drive. The follow

Page 49

REV 2 TTRA-S2 VERSION 1.x SOFTWARE MANUAL 6 3.0 STARTING AND CONFIGURING THE TTRA-S2 SOFTWARE During the installation process, a Vanguard progr

Comments to this Manuals