INSTALLATION
WALL SWITCH INSTALLATION
Since the VDVF36 series models use a valve that operates on
millivolt current generated by the pilot, a wall switch may be used
to activate the gas control valve without the use of normal household
electricity.
1. To remove the louvers, simultaneously pull both top end spring
latches towards the center of the appliance until they are dis-
engaged from locating holes. Repeat for bottom end spring
latches and pull outward. Reverse the procedure to install lou-
vers back onto the appliance (see Figure 32).
Figure 32 - Removing Louver
Glass
Locating
Holes
Spring
Latch
VENTING INSTALLATION
Continued
D1000 7" x 12" Galvanized Coaxial Pipe (6 pcs.)
D1010 7" x 24" Galvanized Coaxial Pipe (6 pcs.)
D1020 7" x 48" Galvanized Coaxial Pipe (6 pcs.)
D1030 7" Adjustable (7-12") Galvanized Coaxial Pipe
(6 pcs.)
D1050 7" x 6" Galvanized Coaxial Pipe (6 pcs.)
D2000 7" x 90° Elbow (6 pcs.)
D2010 7" x 45° Elbow (6 pcs.)
D2060 7" x 45° Starter Elbow
D3000 Wall Strap/Offset Support (6 pcs.)
D3010 Storm Collar (6 pcs.)
D3020 Wall Thimble (6 pcs.)
D3050 Vertical Restrictor (6 pcs.)
D3060 Ceiling Firestop/Support (6 pcs.)
D3070 Rectangular Horizontal Rigid Vent Termination Cap
D3090 Cathedral Ceiling Support Box
D4000 Roof Flashing 6/12-9/12
D4010 Roof Flashing 9/12-12/12
D4020 Flex Connector (6 pcs.)
D4030 Flex Wall Thimble (6 pcs.)
D4040 4" Hose Clamp (6 pcs.)
D4050 7" Hose Clamp (6 pcs.)
D5000 Vinyl Siding Standoff (6 pcs.)
Simpson Dura-Vent GS 4" x 6
5
/8 "
Number Description
902 7" x 48" Pipe
903 7" x 36" Pipe
904 7" x 24" Pipe
906 7" x 12" Pipe
907 7" x 9" Pipe
908 7" x 6" Pipe
Vanguard Flexible Venting
Number Description
FGFVK Flex Ground Floor Vent Kit
Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4'
Flexible Pipe, Wall Thimble, Horizontal Termination,
(4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose
Clamps, RTV Silicone, and 10 Screws
D1040 7" x 25' Coaxial Flex Pipe with Spacer Springs
D3080 Rectangular Horizontal Flex Termination Cap
Vanguard Rigid Venting
(Cont.)
Number Description
VENTING INSTALLATION
Parts Lists for Venting Kits and Components (Cont.)
INSTALLATION
Wall Switch Installation
911 7" Adjustable (11"-14
5
/8") Pipe
940 Wall Thimble
941 Cathedral Ceiling Support Box
943 Roof Flashing 0/12-6/12
943S Roof Flashing 7/12-12/12
945 7" x 45° Elbow
950 Vinyl Siding Standoff
953 Storm Collar
963 Ceiling Firestop
981 36" Snorkel Termination
984 Horizontal Termination Vent Cap
988 Wall Strap
990 7" x 90° Elbow
991 Vertical High Wind Termination