UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service, or maintenance can cause
injury or property damage. Refer to this
manual for correct installation and opera-
tional procedures. For assistance or addi-
tional information consult a qualified installer,
service agency, or the gas supplier.
WARNING: This appliance has been spe-
cifically tested and design certified for
installation only in a solid-fuel burning
fireplace, including factory-built UL127
fireplaces and masonry fireplaces, or in a
listed ventless firebox
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) from the room
in which it is installed. Provisions for
adequate combustion and ventilation air
must be provided. Refer to
Air for Com-
bustion and Ventilation
section on page 4
of this manual.
18" and 24" Variable
Manually-Controlled Models
FLAME-MAX
®
Vintage
Oak Log Design
OWNER’S OPERATION AND INSTALLATION MANUAL
Models Also Design Certified as Vented Decorative Appliances
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
®
Patent Pending
18", 24", and 30" Variable
Manually-Controlled Model
FLAME-MAX
®
Birch
Log Design
®
FLAME-MAX
®
Golden
Oak Log Design
18", 24", 30", and 36" Variable
Manually-Controlled and
18", 24", and 30" Thermostati-
cally Controlled Models
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - PROPANE/LP GAS LOG HEATER

Save this manual for future reference.UNVENTED (VENT-FREE)PROPANE/LP GAS LOG HEATERWARNING: If the information in thismanual is not followed exactly,

Page 2 - WARNING ICON G 001

10104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®INSTALLATIONContinuedINSTALLING DAMPERCLAMP ACCESSORY FORVENTED OPERATIONNote: When used

Page 3

11104343OWNER’S MANUALMasonry ScrewFigure 12 - Attaching Base Assembly to Fireplace FloorBracket withScrew HolesStandard OakLog ChassisGolden Oak and

Page 4

12104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®INSTALLATIONContinuedTee JointPipeNippleCap3" MinimumSediment TrapGasRegulatorFrom E

Page 5

13104343OWNER’S MANUALONPOSITIONOFFPOSITIONINSTALLATIONContinuedFigure 15 - Manual Shutoff ValveOpenClosedManualShutoffValveFigure 16 - Checking Gas J

Page 6

14104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®INSTALLATIONContinued WARNING: Failure to positionthe parts in accordance with thesediagr

Page 7

15104343OWNER’S MANUAL1. STOP! Read the safety informationabove.2. Make sure manual shutoff valve isfully open.3. Press in and turn control knob clock

Page 8

16104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®OPERATINGHEATERContinuedTO TURN OFF GASTO APPLIANCEShutting Off Heater1. Press in and tur

Page 9

17104343OWNER’S MANUALINSPECTINGBURNERSCheck pilot flame pattern and burner flamepatterns often.PILOT FLAME PATTERNFigure 26 shows a correct pilot fla

Page 10 - VANGUARD FLAME-MAX

18104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®TROUBLESHOOTINGNote: All troubleshooting items are listedin order of operation. WARNING:

Page 11 - OWNER’S MANUAL

19104343OWNER’S MANUALTROUBLESHOOTINGContinuedOBSERVED PROBLEMBurner does not light after ODS/pilot is litDelayed ignition burnerBurner backfiring dur

Page 12

2104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®SAFETYINFORMATION DANGER: Carbon monoxidepoisoning may lead to death!Carbon Monoxide Poiso

Page 13

20104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to l

Page 14

21104343OWNER’S MANUALOPTIONALPOSITIONING OFTHERMOSTATSENSING BULBFOR MASONRY ANDFACTORY-BUILT METALFIREPLACEIf your log set cycles to pilot, but ther

Page 15

22104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®SPECIFICATIONSVintage Oak Vintage Oak Golden Oak and Birch18" Variable 24" Vari

Page 16

23104343OWNER’S MANUALNote: Use only original replacement parts.This will protect your warranty coverage forparts replaced under warranty.Parts Under

Page 17

24104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®ILLUSTRATEDPARTSBREAKDOWNFLAME-MAX™VINTAGE OAK MODELSVYS18P AND VYS24P4123122110112172156

Page 18 - TROUBLESHOOTING

25104343OWNER’S MANUALPARTS LISTVYS18PVYS24PThis list contains replaceable parts used in your heater. When ordering parts, follow theinstructions list

Page 19 - Continued

26104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®ILLUSTRATEDPARTSBREAKDOWNFLAME-MAX™ GOLDEN OAKAND BIRCH LOG MODELSVYD18P, VYBD18P, VYD24P

Page 20 - IMPORTANT:

27104343OWNER’S MANUALPARTS LISTVYD18P, VYBD18PVYD24P, VYBD24PVYD30P, VYBD30PVYD36PThis list contains replaceable parts used in your heater. When orde

Page 21

28104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®ILLUSTRATEDPARTSBREAKDOWNTHERMOSTATICALLY-CONTROLLED MODELSVYD18PTVYD24PTVYD30PT121218161

Page 22 - SPECIFICATIONS

29104343OWNER’S MANUALThis list contains replaceable parts used in your heater. When ordering parts, follow the instructionslisted under Replacement P

Page 23 - MAINTENANCE

3104343OWNER’S MANUALLOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absence of local codes,use the latest edition of The N

Page 24 - BREAKDOWN

30104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®ACCESSORIESPurchase these heater accessories from yourlocal dealer. If they can not suppl

Page 25

31104343OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Page 26

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Page 27 - PARTS AVAILABLE — NOT SHOWN

4104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®AIR FORCOMBUSTION ANDVENTILATIONUnusually Tight ConstructionThe air that leaks around door

Page 28

5104343OWNER’S MANUALDETERMINING FRESH AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this work sheet to determ

Page 29

6104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®AIR FORCOMBUSTION ANDVENTILATIONContinuedVENTILATION AIRVentilation Air From InsideBuildin

Page 30 - TECHNICAL

7104343OWNER’S MANUALNOTICE: Manual control heatersmay be used as a vented product.If so, you must always run heaterwith chimney flue damper open.If r

Page 31

8104343UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX®INSTALLATIONContinuedMinimum Non-combustibleMaterial ClearancesIf Not Using MantelYou must

Page 32 - WARRANTY INFORMATION

9104343OWNER’S MANUALFigure 7 - Minimum Mantel Clearances When Using HoodMinimum Non-Combustible Material 8"Min.12" 15" 18"All min